a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Acoustic imaging

Fluke ii915 Acoustic Imager

Fluke ii915 Acoustic Imager: Detect, Locate, and Assess Anomalies

The Fluke ii915 Acoustic Imager is a powerful tool designed to identify and evaluate issues in various systems. With three distinct modes—LeakQ™, PDQ™, and MecQ™—this innovative device empowers maintenance professionals to take proactive measures and prevent costly problems. Let’s explore its capabilities:

Leak Detection with More Sensitivity
LeakQ™ Mode: Detect Hidden Costs


Leaks in compressed air, gas, steam, and vacuum systems can lead to significant financial losses. The Fluke ii915 simplifies leak detection by allowing technicians to visualize sound. As they scan hoses, fittings, and connections, the built-in acoustic array captures decibel levels per frequency. The resulting SoundMap™ overlays on a visual image, making it easy to pinpoint leaks—even during peak operation hours. Say goodbye to time-consuming inspections and hello to efficient leak detection. Fluke ii915 has the high frequency range and best sensitivity to do acoustic leak detection more efficiently.

Early Mechanical Issue Identification
MecQ™ Mode: Efficient Inspection for Conveyor Systems


Conveyor systems are notorious for their complexity and potential to disrupt production. The Fluke ii915 acoustic camera revolutionizes inspection by enabling contactless scanning of large areas. Advanced noise filtering ensures clear images, even in high-noise environments. Detecting potential mechanical issues early allows targeted maintenance, preventing unplanned downtime. For seamless operation and proactive maintenance of large conveyance systems, the Fluke ii915 Acoustic Imager with MecQ™ is the ultimate choice.

Visualizing the Invisible Threat
PDQ™ Mode: Locating Partial Discharge


Partial discharge poses serious risks, from arc flash fires to blackouts. The Fluke ii915 translates partial discharge sounds into visuals, precisely pinpointing their location. With an extended frequency range of 2-100 kHz, this tool can detect partial discharge even earlier and aids maintenance planning to prevent catastrophic events. High-voltage electricians, electrical test engineers, and grid maintenance teams can now see what was once invisible.

Key features
• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.
Download
Produk Lainnya
Fluke ii915 Acoustic Imager
Fluke ii915 Acoustic Imager
Fluke ii915 Acoustic Imager: Detect, Locate, and Assess Anomalies

The Fluke ii915 Acoustic Imager is a powerful tool designed to identify and evaluate issues in various systems. With three distinct modes—LeakQ™, PDQ™, and MecQ™—this innovative device empowers maintenance professionals to take proactive measures and prevent costly problems. Let’s explore its capabilities:

Leak Detection with More Sensitivity
LeakQ™ Mode: Detect Hidden Costs


Leaks in compressed air, gas, steam, and vacuum systems can lead to significant financial losses. The Fluke ii915 simplifies leak detection by allowing technicians to visualize sound. As they scan hoses, fittings, and connections, the built-in acoustic array captures decibel levels per frequency. The resulting SoundMap™ overlays on a visual image, making it easy to pinpoint leaks—even during peak operation hours. Say goodbye to time-consuming inspections and hello to efficient leak detection. Fluke ii915 has the high frequency range and best sensitivity to do acoustic leak detection more efficiently.

Early Mechanical Issue Identification
MecQ™ Mode: Efficient Inspection for Conveyor Systems


Conveyor systems are notorious for their complexity and potential to disrupt production. The Fluke ii915 acoustic camera revolutionizes inspection by enabling contactless scanning of large areas. Advanced noise filtering ensures clear images, even in high-noise environments. Detecting potential mechanical issues early allows targeted maintenance, preventing unplanned downtime. For seamless operation and proactive maintenance of large conveyance systems, the Fluke ii915 Acoustic Imager with MecQ™ is the ultimate choice.

Visualizing the Invisible Threat
PDQ™ Mode: Locating Partial Discharge


Partial discharge poses serious risks, from arc flash fires to blackouts. The Fluke ii915 translates partial discharge sounds into visuals, precisely pinpointing their location. With an extended frequency range of 2-100 kHz, this tool can detect partial discharge even earlier and aids maintenance planning to prevent catastrophic events. High-voltage electricians, electrical test engineers, and grid maintenance teams can now see what was once invisible.

Key features
• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.
Fluke ii500 Acoustic Imager
Fluke ii500 Acoustic Imager
Fluke ii500 Acoustic Imager with LeakQ™: Detect, Locate, and Capture Gas Leaks
The Fluke ii500 Acoustic Imager, equipped with LeakQ™ technology, empowers maintenance teams to detect and locate gas leaks efficiently. Designed for ease of use, it requires no specialized training. Even during peak production periods, teams can effectively identify gas and vacuum leaks. The ii500's advanced acoustic leak detection technology isolates leak sound frequencies, making leaks visible even in noisy environments.

Key features
• Ready-to-Use: The Fluke ii500 is ready out of the box. Its rugged, ergonomic design ensures easy handling, while the large 7" LCD display allows for clear leak visualization.
• Quick Detection: Even users with minimal experience can start detecting leaks within minutes. The tool estimates relative leak size and cost, incorporating a new distance-estimation feature and the 1-10 LeakQ™ severity index.
• SoundMap™ Overlay: The 7" LCD touchscreen overlays a SoundMap™ on visual images, facilitating rapid leak location identification.
• Intuitive Interface: Easily isolate leak sound frequencies and filter out background noise.
• Tagging and Organization: Use image and video tagging, annotation, and folders for efficient organization.
• Leak Sizing: Prioritize repairs based on relative leak size.
• Collaboration: The reporting tool allows sharing of visuals, tagging, and notes with team members and repair personnel.
Logo Header  Footer
Instagram
Facebook
Linkedin
Kantor Pusat
Jl.Wijaya Kusuma Raya Blok C10 No 10, Bekasi Jaya Indah (BJI) Danita, Bekasi 17112 - Indonesia
(021) 2908-5810
office@nrs.co.id
2025 ©distributor fluke. All Rights Reserved
Whatsapp Detail Produk