a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Product

Calibrator

Fluke 6102 7102 7103 MicroBath Thermometer Calibrators
Fluke 6102, 7102, 7103 Micro-Bath Thermometer Calibrators
Portable and extremely stable
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.015 °C
• Ranges from –30 °C to 200 °C

Need portability and extreme stability? Fluke 6102, Fluke 7102, and Fluke 7103 Micro-Baths have both. We invented the Micro-Bath. And, while many have tried to duplicate it, none of them use proprietary Fluke Calibration controllers, so none of them deliver performance like a Fluke Calibration bath. Micro-Baths can be used anywhere for any type of sensor. The 6102 weighs less than 4.5 kg (10 lb.), with the fluid. It’s lighter and smaller than most dry-wells, has a spill-proof lid, and is easier to carry than your lunch. You can take it where you need to go without carts or excessive effort. Micro-Baths can even be transported with the fluid in them.
Fluke 9190A UltraCool Field Metrology Well
Fluke 9190A Ultra-Cool Field Metrology Well
Key features
Ultra-cool dry-block calibrator with best-in-class stability

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It’s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers.

Wide temperature range
–95 °C to 140 °C

Excellent accuracy
Accuracy using built-in referencethermometer readout: ±0.05 °C full range
Display accuracy: ±0.2 °C full range
Best-in-class stability
±0.015 °C full range

Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes

Portability
Weighs only 16 kg (35 lbs)
Built-in front and back handlesfor easy two-handed carry
Best measurement practices
Conforms with EURAMET cg-13 guidance on measurement practices for temperature calibrators
Fluke Calibration 9142 Field Metrology Well
Fluke Calibration 9142 Field Metrology Well
Key features
• Lightweight, portable, and fast
• Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
• True reference thermometry with accuracy to ±0.01 °C
• On-board automation and documentation
• Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9132 and 9133 Portable Infrared Calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:
• Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design in a blackbody calibrator

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact temperature measurement.
Fluke 4180 4181 Precision Infrared Calibrators
Fluke 4180, 4181 Precision Infrared Calibrators
Accuracy and traceability for infrared measurements

Now it’s easy to increase your IR temperature measurement accuracy with the new 4180, 4181 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

New accredited performance for point-and-shoot calibrations
• Calibrated radiometrically for meaningful, consistent results.
• Accredited calibration included
• Accurate, reliable performance from –15 °C to 500 °C
• Large target size of 152 mm (6 in) is required for calibrating most thermometers.
• Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
• Intuitive, easy-to-read display that indicates when temperature is stable.