Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators

Great performance in portable instruments
• Lightweight and very portable
• Accuracy to ±0.25 °C
• RS-232 interface
• Easy to recalibrate

If you’ve been using a dry well calibrator or dry block calibrator for field work, you know there’s a lot more to them than temperature range and stability. Size, weight, speed, convenience, and software are also significant.

A field dry well needs to be portable, flexible, and suitable for high-volume calibrations or certifications. If it's not, you’ll soon forget about the great stuff the sales rep told you and realize what you’ve really bought.

At Fluke Calibration, we use dry well calibrators every day in our manufacturing and calibration work, and we know what makes a dry well easy and productive to use—which is exactly how users describe our series of field dry wells. These dry wells work for you instead of the other way around.
Download
Produk Lainnya
Fluke 9103 9140 DryWell Calibrators  Dry Block Calibrators
Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators
Great performance in portable instruments
• Lightweight and very portable
• Accuracy to ±0.25 °C
• RS-232 interface
• Easy to recalibrate

If you’ve been using a dry well calibrator or dry block calibrator for field work, you know there’s a lot more to them than temperature range and stability. Size, weight, speed, convenience, and software are also significant.

A field dry well needs to be portable, flexible, and suitable for high-volume calibrations or certifications. If it's not, you’ll soon forget about the great stuff the sales rep told you and realize what you’ve really bought.

At Fluke Calibration, we use dry well calibrators every day in our manufacturing and calibration work, and we know what makes a dry well easy and productive to use—which is exactly how users describe our series of field dry wells. These dry wells work for you instead of the other way around.
Fluke 4180 4181 Precision Infrared Calibrators
Fluke 4180, 4181 Precision Infrared Calibrators
Accuracy and traceability for infrared measurements

Now it’s easy to increase your IR temperature measurement accuracy with the new 4180, 4181 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

New accredited performance for point-and-shoot calibrations
• Calibrated radiometrically for meaningful, consistent results.
• Accredited calibration included
• Accurate, reliable performance from –15 °C to 500 °C
• Large target size of 152 mm (6 in) is required for calibrating most thermometers.
• Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
• Intuitive, easy-to-read display that indicates when temperature is stable.
Fluke 9101 ZeroPoint DryWell
Fluke 9101 Zero-Point Dry-Well
Ice-point reference without the ice
• Bath-quality stability in a portable ice-point reference
• Easy re-calibration for long-term reliability
• Ready-light frees user’s time and attention
• Solid-state cooling technology

Have you been thinking about buying a zero-point dry-well? Forget those ugly-looking units the competition makes. You can get a great looking and great performing zero-point dry-well from Fluke Calibration.

The 9101 has three test wells for inserting more than one probe at a time. All three wells are stable to ±0.005 °C. One well accommodates changeable inserts for varying probe diameters.
Fluke 9118A Thermocouple Calibration Furnace
Fluke 9118A Thermocouple Calibration Furnace
High performance furnace for thermocouple calibrations to 1200 °C

The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics. The 9118A is the most accurate, reliable, and flexible furnace in its class, meeting the demanding requirements of high-temperature thermocouple calibration.