a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Calibrator

Fluke 9100S, 9102S Handheld Dry-Wells

World’s smallest, lightest and most portable dry-wells
• Smallest dry-wells in the world
• Ranges from –10°C to 375°C
• Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
• RS-232 interface

Fluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!
Download
Product Lainnya
Fluke Calibration 9142 Field Metrology Well
Fluke Calibration 9142 Field Metrology Well
Key features
• Lightweight, portable, and fast
• Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
• True reference thermometry with accuracy to ±0.01 °C
• On-board automation and documentation
• Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9011 HighAccuracy DualWell Calibrator
Fluke 9011 High-Accuracy Dual-Well Calibrator
Widest temperature range available in a single dry-well
• Combined range from –30 °C to 670 °C, one unit – two blocks
• Two independent temperature controllers (hot and cold side)
• Stability to ±0.02 °C
• Multi-hole wells for calibrating up to eight probes simultaneously

To give you the widest temperature range available in a dry-well calibrator, we’ve combined two of our most popular units. The 9011 allows temperature probes to be calibrated from –30 °C to 670 °C in a single unit.
Fluke 9132 and 9133 Portable Infrared Calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:
• Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design in a blackbody calibrator

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact temperature measurement.
Fluke 700PTP1 Pneumatic Test Pump
Fluke 700PTP-1 Pneumatic Test Pump
The Fluke-700PTP-1 pneumatic test pump is capable of supplying pressures up to 600 psi, 40 bar.
For use with 700 series pressure modules or test gauges. Can be directly connected to the reference port consolidating two separate pieces when performing pressure calibration and testing. Can also be used with 717 pressure calibrators. Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar.

Fitur utama
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
o 1/4 in NPT female fitting for the reference gauge or pressure module
o 1/8 F-NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke
• Vacuum range from -12.7 psi or -.87 bar, pressure range up to 600 psi or 41 bar
Logo Header  Footer
Instagram
Facebook
Linkedin
Head Office
Jl.Wijaya Kusuma Raya Blok C10 No 10, Bekasi Jaya Indah (BJI) Danita, Bekasi 17112 - Indonesia
(021) 2908-5810
office@nrs.co.id
Copyright © 2026 PT Narmada Setia. All Rights Reserved
Whatsapp Detail Produk