a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
08111333128
Calibrator

Fluke 9100S, 9102S Handheld Dry-Wells

World’s smallest, lightest and most portable dry-wells
• Smallest dry-wells in the world
• Ranges from –10°C to 375°C
• Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
• RS-232 interface

Fluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!
Download
Product Lainnya
Fluke Calibration 6531 6532 EDWT Electronic Deadweight Tester Kits
Fluke Calibration 6531, 6532 E-DWT Electronic Deadweight Tester Kits
Fluke Calibration electronic deadweight tester kits feature E-DWT-H configurations combined with the accessories needed for a complete calibration system. Model 6531 options feature E-DWT-H configurations with a single quartz reference pressure transducer (Q-RPT) to offer percent of reading performance from 10 % to 100 % of device full scale. Model 6532 options feature an additional Q-RPT to maximize workload coverage, with percent of reading performance from 1 % to 100 % of device full scale. An included vacuum fill kit allows the E-DWT to be filled with your choice of compatible fluid, while eliminating problematic air pockets from the test circuit. Also included is a test station adapter to mount just about any pressure device to be tested without using PTFE tape or wrenches. 6531 and 6532 kits provide all you need to perform high level hydraulic pressure calibration right out of the box.
• Pressure ranges available to 200 MPa (30,000 psi)
• ± 0.02 % of reading total one-year accuracy, 0.025 % for two years
• Low torque variable volume allows for pressure generation and control up to 200 MPa (30,000 psi) with minimal physical effort
• Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
• Unique test port design eliminates the need for PTFE tape or wrenches. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5
• Compatible with a wide range of liquids, including water. Vacuum fill kit included to fill the E-DWT with any compatible test medium
• AutoTest™, AutoRange, ready/not ready indicator, onboard data capture and storage, overpressure alarm, RS-232 remote interface and other advanced features to simplify testing, improve safety and prevent calibration errors and damage to equipment
• Optional foot switch accessory allows hands-free data collection when running AutoTests
• Rechargeable battery pack and transport case options for field operation

Key Features
• Eliminates the need for weights and piston-cylinder changes.
• Real-time pressure indication without need for corrections.
• Set and read any pressure value exactly, operates in any unit of measure, and can switch easily between units.
• Offers ± 0.02% of reading total one-year measurement uncertainty.
Fluke 9118A Thermocouple Calibration Furnace
Fluke 9118A Thermocouple Calibration Furnace
High performance furnace for thermocouple calibrations to 1200 °C

The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics. The 9118A is the most accurate, reliable, and flexible furnace in its class, meeting the demanding requirements of high-temperature thermocouple calibration.
Fluke 730HTP70M
Fluke 730HTP/70M
The New Fluke 730 series portable pumps feature fast pressure generation,stable pressure and easy-to-use. These pumps can provide stable,reliable pressure during calibration. The unique design of these pumps enables them to solve the common problems of pressure pump, such as blocking, leakage and laborious operation. They are your right-hand assistant in the process of manual pressure calibration.
In conjunction with Fluke 730G Smart Digital Pressure Calibrator with internal HART communication, these test pumps enable high-efficiency and high-accuracy measurement and calibration of pressure gauges, pressure switches, pressure transmitters, which make them ideal for metrology institutes and enterprises to establish pressure laboratories.

Key features
• Pressure range 0 kPa to 70 Mpa
• The pressure generation by the pressure rod can calibrate pressure meters with a large cavity;
• fine adjustment by the screw has the high minimum controllable adjustment granularity
• Two-year warranty. No worry to use.
• Special surface treatment, scratch and corrosion resistance.
• M20×1.5 female thread quick connection fitting.
Fluke 8808A Digital Multimeter
Fluke 8808A Digital Multimeter
It is remarkably easy to use, even by unskilled operators, because it makes the measurements you perform most often extremely easy and fast to do.
Six setup buttons on the 8808A front panel operate like a car radio’s station presets. Simply set up the meter for a common measurement, then press shift followed by a setup button (S1 to S6) to save the setup. Now each time you perform that measurement, you simply press the appropriate setup key. It’s that easy!
The setup buttons eliminate the need to follow complex work instruction sheets. Operators no longer need to press multiple buttons to set up a measurement function and range, test limits, or enter other parameters to make a measurement.

Eliminate production mistakes

The Fluke 8808A 5.5 digit multimeter dependably performs the most common measurements required by today’s applications. Whether you are performing functional tests or making critical measurements on test points, using the limit compare mode with pass/fail indicators eliminates production mistakes, especially those where results are “on the edge.” The 8808A display has built-in enunciators that clearly show the operator whether a test passes or fails. The pass/fail indicators take the guesswork out of testing: the result is either within limits or it’s out!
Improve quality and efficiency in manufacturing test, R&D or service applications
Manufacturing test, R&D, development and service applications demand performance and flexibility from a bench meter. This Fluke 8808A makes measurements that stand up to any scrutiny. It delivers a wide variety of measurement functions, including volts, ohms, and amps, plus frequency—all at superior accuracy and resolution.

Measure two parameters at once

The 8808A features a unique dual display that allows you to measure two different parameters of the same signal from one test connection. Looking at dual interrelated parameters like voltage and current simultaneously can reveal conditions that might go unnoticed otherwise, greatly simplifying test and troubleshooting.

Measure sensitive leakage current

Typical multimeters use a shunt method to measure current, creating a measurement burden voltage that increases the error in low current measurements. This makes it difficult, if not impossible, to perform tasks such as determining the true leakage current on a battery-powered device while it is powered down, or measuring small currents in sensitive circuits. The Fluke 8808A is the only multimeter in its class to use a low-impedance operational amplifier and current-to-voltage conversion technique to eliminate the burden voltage and measure sensitive low currents. In this special mode, the 8808A can accurately measure small currents with a resolution of up to 100 nA.

Perform 4-wire measurements with only two leads

Patented split terminal jacks for the 2x4-wire ohms function allow you to perform 4-wire measurements using only two leads instead of four. Today’s surface mount components make it difficult to make connections. The task becomes even more difficult when you need to use a 4-wire technique for accurate low ohms measurements. The Fluke test lead accessory combines the four wires into two test lead pairs, making it easy for you to establish connections. You get excellent resolution and accuracy, plus the convenience and ease of using a single pair of leads.

Key features
Versatile, 5.5 digit bench multimeter for manufacturing, development and service applications
• 5.5 digit resolution
• Basic V DC accuracy of 0.015%
• Dual display
• Dedicated DC leakage current measurement
• 2 x 4 ohms 4-wire measurement technique
• Six dedicated buttons for fast access to instrument setups
• Hi/Lo limit compare for Pass/Fail testing
• Three-year warranty
Logo Header  Footer
Instagram
Facebook
Linkedin
Head Office
Jl.Wijaya Kusuma Raya Blok C10 No 10, Bekasi Jaya Indah (BJI) Danita, Bekasi 17112 - Indonesia
(021) 2908-5810
office@nrs.co.id
Copyright © 2026 PT Narmada Setia. All Rights Reserved
Whatsapp Detail Produk